Once you’ve added your sites, users, workflows, and sensors, it’s important to run a quick system check to ensure everything is working as expected. Testing your setup helps you confirm that:
Sensors are reporting correctly
Alerts are triggering as intended
Workflows appear for the correct sites and users
Mobile access is set up properly
Your reporting dashboard is accurate
This guide walks you through a simple checklist to validate your full Telsen setup before launching with your team.
1) Confirm Sensors & Gateways Are Online
Check Device Status
Log in to Telsen on desktop.
Go to Devices
Ensure all sensors show green (online).
What to look for
Temperature readings updating every 10 minutes
No unexpected transmission gaps
Optional Test
Open a fridge door for a few minutes to confirm the graph updates and the Amber warning triggers after crossing the
2) Test Your Alert Configuration
Go to Manage Alerts.
Check that each sensor is assigned to the correct alert rules.
Verify users are assigned at the correct sites.
Trigger a Live Test (Optional)
If appropriate, create a controlled test:
Temporarily raise the threshold on a non-critical sensor
Wait for the sensor to go Amber → Red
Confirm users receive alerts on email, or push notifications
Check Corrective Actions
Respond to an alert by logging a corrective action
Watch for the alert returning to green once temperature normalises
Check the report
This ensures both alerts and action logging work as expected.
3) Check Workflows on Mobile
Ask a team member (or yourself) to log in on the mobile app.
Scheduled Workflows
Confirm today’s scheduled workflows appear in the Workflows tab
Verify start/end times
Open the workflow to ensure questions display correctly
Adhoc Workflows
Tap the + in the Workflows tab
Ensure all expected adhoc workflows appear
Start one to confirm it loads properly
Submit or save as draft
This validates your workflow scheduling and permissions are set correctly.
4) Test HACCP Checks (If Applicable)
Complete one HACCP workflow on mobile:
Probe connects correctly (if enabled)
Temperature automatically populates
Corrective action is required if temp is out of range
Workflow submits without errors
This ensures your food-safety processes are fully operational.
5) Review Reporting
Navigate to Reports to confirm your data is feeding through:
Site Report: Shows workflows, alerts, corrective actions
HACCP Report: Displays completed and pending compliance checks
Custom Workflow Report: Shows activity for operational workflows
Sensors Report: Confirms historical readings and gaps
Look for:
Accurate timestamps
Completed workflows appearing immediately
Alerts displaying under the correct site
No unexpected missing data
Final Pre-Launch Review
Before rolling out to your full team:
All sensors reporting ✔
Alerts configured and notifying correctly ✔
Workflows assigned to correct sites & users ✔
HACCP checks functioning as expected ✔
Reports showing accurate data ✔
Users can log in and complete tasks ✔
Your Telsen setup is now ready for daily use.